Download Installation and operation manual of gefran 450-R-R-1 Controller for Free or View it Online on All-Guides.com. This version of gefran 450-R-R-1 Manual compatible with such list of devices, as: 450-R-R-1, 450-R-R-0, 450-D-R-1, 450-D-R-0
Brand: gefran
Category: Controller
1000 / 1001 / 1101 CONFIGURABLE TEMPERATURE CONTROLLERS SOFTWARE VERSION 13.x code 80343G / Edition 19 -11/07 INSTALLATION AND OPERATION MANUAL 96 108 96 115 92 92 100 10 115 48 108 96 70 115 92 44,5 100 10 For correct and safe installation observe the warnings contained in this manual 1 • INSTALLATION • Dimensions and cut-out; panel.
Type: Installation and operation manual
Model: gefran 450-R-R-1 , gefran 450-R-R-0 , gefran 450-D-R-1 , gefran 450-D-R-0
Pages: 18
More information and the Declaration of Conformity can be found at service and support on:www.paulgothe.de10/17
Wittener Straße 82
Manual
Temperature controller (36.022and 36.022-DUO)
Before use check the electrical condition of the appliance. For your safety: Don’t connect with the power
The temperature controller can be used in conjunction with the permissible temperature sensors
according to specification for controlling of heating elements / cartridges.
More information and the Declaration of Conformity can be found at service and support on:
1 Connect the temperature couple to the NiCr-Ni port.
2 Connect the power supply from the heating cartridges / heating elements at the electric socket.
3 Connect the power supply from the controller and meet all necessary protective measures according
to local regulations.Use the power switch at the rear to turn the unit on.
5 Heating modes are indicated by left LED(left LED indicates heating, right LED permanent light).
6 Device is provided with a breakage protection element. Should the temperature couple fail, no
7. If temperature more as 400 °C the alarm function will be activated and heating stopped (right LED
Technical Data
Housing: Material: Makrolon ® (thermoplast. polycarbonate plastic)
Supply voltage: max. 230 V, 48 ... 62 Hz
Operating range: depending on the temperature sensor NiCr-Ni: 20 ... 390 °C
Output voltage: 2 x max. 250 V, max. 5 A, circuit via contactor for heating
If at the power exit is no 220V ('not heating'):
Please disconnect controller from power and open the cover:
1. Please check the fuse at the main switch and the fuse inside the unit (DUO: fuses) and replace them
if necessary (5 A slow-blow, only the DUO-Version: fuse at the main switch: 10 A).
2. If fuse is OK, please replace relay (replacement relay is glued). Instructions for replacing the relay
can be found on our website under Service and Support.
If the controller continuously supplies 220V ('don’tregulate but constant power'):
1. Exchange the relay (replacement relay is glued). Instructions for replacing the relay can be found